An analysis of the minizone

The amount of sample being purified will determine which tubing size is selected and the number of tubes to be used.

This Zone Refiner Simu- lator Program helps greatly in understanding the power and limitations of the zone refining technique. The top inch of solid benzene was melted and a sample condensed into one of the capillaries.

The sample is usually purified within 18 hours of automatic operation 18 recrystallizations.

The benzene, introduced through a silica gel filter, was then frozen by means of liquid nitrogen. The references for the above list are as follows: Dissolved gases were removed by four sublimations between the two cold traps; the first two sublimations were made with the aid of liquid nitrogen and the other two by the use of a carbon dioxide acetone freezing mixture.

Out gassing of the sample when crystallization occurs. Analysis of the sample gave C, Remove these plugs and save them for future use. The sample may be removed from each section by dissolving in a suitable solvent, melting the sample or by physically pushing the solid sample from the tubing.

One or two disposable, thin-walled PFTE sample tubes filled with the sample are clamped on each end in the tube transport mechanism the metal blocks at the top and bottom of the photo.

Zone refined material exhibited ohmic resistivity with an energy gap of I 6 eV and this was considered to be a good value. We have developed a short computer program that allows the rapid calculation of zone refiner oper- ation.

Anthraquinone Wynne reported that the melting point of a zone refined sample was A minimum of about 0. At the melting interface the sample is merely melted and mixed with the contents of the molten zone.

Anthracene Wolf reported that tetracene can be removed from anthracene by zone refining. Wynne reported that the melting point of a zone refined sample was When technical benzene containing approximately 0.

Most impurities are concentrated at one end of the tube. Sample Tube does not move up and down.

MiniZone Manual

The original charge contained 2. Vanillin A melting point of This does not include defects due to misuse, abuse, abnormal conditions or operation, accidents, or to service or modification to the unit without prior authorization of the Company.

Zone refining was developed in by William G.• MiniZone Instruction Manual • Package of 12 MiniZone Medium Teflon sample tubes • Package of 12 MiniZone Large Teflon sample tubes Retain all packing materials until the instrument is connected and functioning properly.

Any unit return, regardless of the reason, must have prior approval by Design Scientific, Inc. With a typical zone rate of 2 cm/hr and four active zones, each portion of the sample is subjected to one purifying phase transition per hour.

The sample is usually purified within 18 hours of automatic operation (18 recrystallizations). After the sample tube is cooled, it is removed from the MiniZone. Definition of minizone in the killarney10mile.com dictionary. Meaning of minizone. What does minizone mean?

Information and translations of minizone in the most comprehensive dictionary definitions resource on the web. • Placing the loaded tube in the MiniZone Refiner • Instrument Settings; Purification of the Sample • Removing the purified Sample • Troubleshooting • Concentration of sample impurities for further analysis or identification • Purification of laser dyes • Purification of organic semiconductors.

High-Speed Zone Refining

• Package of 12 MiniZone Medium Teflon sample tubes • Package of 12 MiniZone Large Teflon sample tubes Retain all packing materials until the instrument is connected and functioning properly.

Any unit return, regardless of the reason, must have prior approval by Design Scientific, Inc. All returns should be shipped to the address listed below. EMM-3U UNIVERSAL ELECTRONIC MINIZONEŽ PANEL 4 INSTALLATION Mounting CAUTION Equipment Damage Hazard.

Translation

.

Download
An analysis of the minizone
Rated 0/5 based on 11 review